LPA DC-DC Converter 

DC-DC Converters

Series LPA Single and Series LPA Dual

Isolated Regulated 75 Watts, Wide Input Range/18-36 VDC
Fully Regulated, Short Circuit Protected
Parallel Operation Available

Features:
  • Dual isolated outputs
  • Short circuit protection
  • Input voltage protection
  • Thermal, over temp. shutdown
  • Line regulation
  • Load regulation
  • No external components required
  • Hi density, hi efficiency design
  • Remote shutdown
  • Trim capabilities
  • Fixed frequency-100 Khtz
Typical Characteristics:

Frequency: 100 Khtz
Base plate: Max. +85° C
Operating temperature: See thermal chart, Min. 0° C ambient, Max. +85° C base plate temp.
Test conditions: 25° C ambient
Isolation Base Input: 2121 VDC
Isolation Input Output: 4242 VDC
Isolation Output to Base: 1000 VDC
Storage temperature: -55° C to +105° C

    21 Standard Models
    Meets MIL STD 704 Surge Requirements
    Fixed Frequency
    For all variations, call factory.

For Parallel Operation: Add suffix "P" (i.e. LPA5SP). Consult factory to optimize for your application.

The new PICO LPA Series of high power DC-DC Converters, allow a wide input voltage of 18-36 VDC, while maintaining a regulated output. They are fully safeguarded for over voltage, over temperature and continuous short circuit protection.

The availability of Dual Isolated Outputs, small size, and the capability of parallel operations as standard features should reduce your design and component costs, while the fixed frequency operation helps parallel connections for higher power requirements.

This high density unit is assembled in the USA with PICO quality and component selection, allowing it to meet the most stringent commercial requirements.


Series LPA Single * 75 Watts * Input 18-36 VDC

Pico
Part
No.

Input
Voltage
Range
(V DC)
Output
Voltage
(V DC)
Max.
Output
Power
*
(W)
EFF.
Full Load
Typical
**
(%)
Max.
Load
Regulation
(%)
Max.
Line
Regulation
At Full Load
(%)
Output
Voltage
Ripple
(Full Load)
1-1MHz BW
(MV P-P)
Output
Voltage
Tolerance
**
(± %)
10-50% 50-100% 18-28 28-36
LPA3.3S 18-36 3.3 30 73 1.5 1.5 1.0 1.0 50 2
LPA5S 18-36 5 50 80 1.25 1.25 1.0 1.0 50 1.5
LPA5.2S 18-36 5.2 50 80 1.25 1.25 1.0 1.0 50 1.5
LPA9S 18-36 9 60 84 1.25 1.25 1.0 1.0 50 1
LPA12S 18-36 12 60 85 1.25 1.25 1.0 1.0 50 0.75
LPA15S 18-36 15 65 85 1.0 1.0 0.75 0.75 50 0.75
LPA24S 18-36 24 75 87 0.75 0.75 0.5 0.5 50 0.75
LPA28S 18-36 28 75 87 0.5 0.5 0.5 0.5 50 0.5
LPA48S 18-36 48 75 85 0.5 0.5 0.5 0.5 50 0.5
LPA100S 18-36 100 75 85 0.5 0.5 0.5 0.5 100 0.5
10% Minimum load required at all times.
* Using proper thermal management, maximum temp. of +85° C (case)
** Reading taken at nominal 28 VDC input

Series LPA Dual * 75 Watts * Input 18-36 VDC

Pico
Part
No.

Input
Voltage
Range
(V DC)
Output
Voltage
(V DC)
Max.
Output
Power
*
(W)
EFF.
Full Load
Typical
**
(%)
Max.
Load
Regulation
(%)
Max.
Line
Regulation
At Full Load
(%)
Output
Voltage
Ripple
(Full Load)
1-1MHz BW
(MV P-P)
Output
Voltage
Tolerance
**
(± %)
10-50% 50-100% 18-28 28-36
LPA5D 18-36 5 50 80 1.25 1.25 1.0 1.0 50 1.5
LPA9D 18-36 9 60 84 1.25 1.25 1.0 1.0 50 1
LPA12D 18-36 12 60 85 1.25 1.25 1.0 1.0 50 0.75
LPA15D 18-36 15 65 85 1.0 1.0 0.75 0.75 50 0.75
LPA24D 18-36 24 75 87 0.75 0.75 0.5 0.5 50 0.5
LPA28D 18-36 28 75 87 0.5 0.5 0.5 0.5 50 0.5
LPA48D 18-36 48 75 85 0.5 0.5 0.5 0.5 50 0.5
10% Minimum load required at all times.
* Using proper thermal management, maximum temp. of +85° C (case)
** Reading taken at nominal 28 VDC input


*** HIGH VOLTAGE SERIES LPA

TO 200 VDC - 50 WATTS - INPUT 18-36 VDC

PICO

PART

NUMBER

INPUT

VOLTAGE

RANGE

(VDC)

OUTPUT

VOLTAGE

(DC)

MAX.

OUTPUT

POWER

(W)*

EFF. @

FULL

LOAD

TYPICAL

(%)**

MAX. LOAD

REGULATION

(%)**

MAX. LINE

REGULATION

AT FULL LOAD

(%)

OUTPUT

VOLTAGE

RIPPLE

FULL LOAD

1-1 MHz BW

(MVP-P)

OUTPUT

VOLTAGE

Tolerance

(±%)**

          20-50% 50-100% 18-28 V 28-36 V    
LPA120S 18-36 125 50 82 0.5 0.5 0.3 0.3 1 0.5
LPA150S 18-36 150 50 82 0.5 0.5 0.3 0.3 1 0.5
LPA175S 18-36 175 50 82 0.5 0.5 0.3 0.3 1 0.5
LPA200S 18-36 200 50 82 0.5 0.5 0.3 0.3 1 0.5
10% Minimum load required at all times

*Using proper thermal management maximum temp. Of +85°C )case.

**Reading taken at nominal 28 VDC input

*** UL recognition pending